Benefits of AP+M Air Filters

Air-filters-apm

Reduced Power Loss

Air-filters-apm

Lowered Operating Costs

Air-filters-apm

Reduced Pressure Drop

Air-filters-apm

Improved Flow

Air-filters-apm

Increased Filter Life

Filter Types

Air-filters-apm

V-bank mini-pleat air filters provide low airflow resistance, high efficiency and prolonged filter life.

For GE Frame & GE LM2500

Air-filters-apm

Customizable conical + cylindrical features with pleated media cartridges for self-cleaning pulse systems or standard non-pulsing systems air filtration.

For GE Frame & GE LM Turbines
(Excluding LM2500 & LM6000)

Air-filters-apm

2-stage static air filter comprised of an inner barrier and cartridge filter for specific air inlet filtration needs.

For LM6000

Media Types

For VPlus, CCplus and CFSplus air filters

Air-filters-apm

Wet laid single blend of cellulose and polyester fibers.

Air-filters-apm

Composite electrospun nano layer bond of cellulose and polyester fibers.

Air-filters-apm

Heavy-duty, 100% polyester spunbond media for durability and protection against particulate release and moisture resistance.

Air-filters-apm

Hydrophobic, 100% synthetic multi-layer composite coating for high efficiency and low operation pressure drop. Prevents salt and water penetration.

Applications

Particle Removal Efficiency

Good

SOLOSHIELD: Good

Excellent

DUODEFENSE: Excellent

Good

POLYPURE: Good

Excellent

HYDROHARBOR: Excellent

Static

Excellent

SOLOSHIELD: Excellent

Excellent

DUODEFENSE: Excellent

Excellent

POLYPURE: Excellent

Excellent

HYDROHARBOR: Excellent

Moisture Resistence

No

SOLOSHIELD: No

No

DUODEFENSE: No

Excellent

POLYPURE: Excellent

Excellent

HYDROHARBOR: Excellent

Performance

Environment

Desert

Tropical

Urban

SOLOSHIELD:

Desert

Tropical

Urban

Desert

Tropical

Urban

DUODEFENSE:

Desert

Tropical

Urban

Arctic

Coastal

Cooling Tower

Desert

Tropical

Urban

POLYPURE:

Arctic

Coastal

Cooling Tower

Desert

Tropical

Urban

Arctic

Coastal

Cooling Tower

Desert

Offshore

Tropical

Urban

HYDROHARBOR: Excellent

Arctic

Coastal

Cooling Tower

Desert

Offshore

Tropical

Urban

Filter Class MERV Rating

MERV 10

SOLOSHIELD: MERV 10

MERV 15

DUODEFENSE: MERV 15

MERV 10

POLYPURE: MERV 10

MERV 15

HYDROHARBOR: MERV 15

Air Permeability

22 cfm

SOLOSHIELD: 22 cfm

26.5 cfm

DUODEFENSE: 26.5 cfm

26 cfm

POLYPURE: 26 cfm

23.4 cfm

HYDROHARBOR: 23.4 cfm

Mullen Burst Strength, Dry

Min 48 psi

SOLOSHIELD: Min 48 psi

Min 50 psi

DUODEFENSE: Min 50 psi

Min 200 psi

POLYPURE: Min 200 psi

Min 20 psi

HYDROHARBOR: Min 20 psi

Capability

Maximum Operation Temperature

200°F

SOLOSHIELD: 200°F

200°F

DUODEFENSE: 200°F

275°F

POLYPURE: 275°F

200°F

HYDROHARBOR: 200°F

Hydrolysis

Good

SOLOSHIELD: Good

Good

DUODEFENSE: Good

Good

POLYPURE: Good

Good

HYDROHARBOR: Good

Acid

Good

SOLOSHIELD: Good

Good

DUODEFENSE: Good

Fair

POLYPURE: Fair

Good

HYDROHARBOR: Good

Alkali

Good

SOLOSHIELD: Good

Good

DUODEFENSE: Good

Fair

POLYPURE: Fair

Good

HYDROHARBOR: Good

MERV Test Results

Particle Size Range

Minimum Initial Efficiency

SOLOSHIELD: Minimum Initial Efficiency

Minimum Initial Efficiency

DUODEFENSE: Minimum Initial Efficiency

Minimum Initial Efficiency

POLYPURE: Minimum Initial Efficiency

Minimum Initial Efficiency

HYDROHARBOR: Minimum Initial Efficiency

E1 (0.3 to 1 micron)

19%

SOLOSHIELD: 19%

85%

DUODEFENSE: 85%

24%

POLYPURE: 24%

85%

HYDROHARBOR: 85%

E2 (1 to 3 micron)

53%

SOLOSHIELD: 53%

98%

DUODEFENSE: 98%

59%

POLYPURE: 59%

97%

HYDROHARBOR: 97%

E3 (3.0 to 10 micron)

94%

SOLOSHIELD: 94%

100%

DUODEFENSE: 100%

94%

POLYPURE: 94%

100%

HYDROHARBOR: 100%

For VPlus air filters ONLY:

Air-filters-apm

100% synthetic composite with high integrity and moisture resistance used as a final filtration to keep compressors clean.

Technical Data

Filter Media

2 Layer Melt-Blown, Non-Woven / Gasket / Neoprene Sponge

Filter Frame

ABS Resin / Potting Sealant / Poly-Urethane

Performance

Environment

Arctic / Coastal / Cooling Tower / Desert / Offshore / Tropical / Urban

Air Flow

2520 cfm

MERV Rating

MERV 16

Initial Pressure Drop

0.033" W.G.

Final Pressure Drop

1.5" W.G.

Average Arrestance

100%

Dust Holding Capacity at 1.5" W.G.

168 g/m2

Temperature Range

158°F

Flame Retardant

UL900

MERV Test Results

E1

96%

E2

100%

E3

100%

Dimensions

Standard Frame

28 3/8 x 23 3/8 in.

Bank Unit

4V

Frame Depth

11 1/2 in.

Header Size

23 3/8 in.

Accessories

Pre-Filter Wraps

Air-filters-apm

Moisture-proof and especially suited for high salt concentration, the Pre-Filter is uniquely suited to protect high-efficiency filter cartridges in gas turbine applications.

Performance

Environment

Arctic / Coastal / Cooling Tower / Desert / Offshore / Tropical / Urban

Air Flow

530 cfm

Velocity

47 fpm

MERV Rating

MERV 8

Initial Pressure Drop

0.1" W.G.

Final Pressure Drop

1.8" W.G.

Average Arrestance

95%

Dust Holding Capacity at 1.5" W.G.

420 g/m2